ONLINE RENTALS MADE EASY

ESD30 30kV ESD Simulator for IEC-EN 61000-4-2

Description

ESD30 ESD Simulator Includes Everything for Testing:

  • ESD30 Handheld, battery operated ESD simulator
  • Battery charger/AC Adapter
  • Air discharge tip
  • Contact discharge
  • Ground cable 1 meter
  • Manual
  • Calibration Certificate
  • 10% off Calibration Service for Life of the Unit


ESD30 30kV ESD Simulator for IEC/EN 61000-4-2

The ESD30 30kV ESD Simulator is suitable for performing EMI tests on systems in accordance with the standard IEC / EN 61000-4-2 , MIL-STD-461G CS118, RTCA/DO-160 Section 25, IEC 60601-1-2 and many other ESD test standards. Higher test levels can be set far beyond the standard limits. Depending on the test object and test setup, two test methods are to be used:

  1. Air Discharge 
    In this case, the pulse is triggered by approaching the ESD16 towards the DUT. The high voltage applied to the discharge electrode is discharged suddenly, resulting in a very broadband highfrequency interference spectrum. This in turn can lead to influences on the test specimens.

  2. Contact Discharge 
    With this method, the probe of the generator is placed directly on the test object. The actual "impulse triggering" takes place via a relay contact and reduces the influencing factors such as approach speed, amplitude height, air humidity and temperature.
    Important: In the case of non-contacting (eg painted or oxidized surface), the impulses are not triggered. The display shows "No contact". This ensures that when triggering a discharge actually takes place.

The contact discharge is the preferred test method since it is most reproducible. Air discharges are used when contact discharges are not possible - e.g. at plastic housings. The test voltages defined for each test method are shown in the table below:

ESD30 Features

  • Programmable discharge voltage 200V to 30kV
  • Stabilized charging voltage
  • Pre-programmed IEC/EN 61000-4-2 test settings
  • True air-discharge breakdown voltage
  • Compact and lightweight design

ESDguns.com is now a division of The EMC Shop

 

Product form

In Stock  In Stock
Monday to friday we offer next day delivery if the product is on stock and exceptions on holidays.

Request Lead Time
Equipment comes and goes everyday, we aren't automated for this website, contact us for status.

International
Depending on where you’re located, we offer next day delivery. Check your status on this link

$10,275.00

      Application/Order Support: 800.794.0349

    Available Mon-Fri 8:00 am to 5:00 pm PST

    • Guaranteed secure & safe checkout.

      <p>Guaranteed <b>secure & safe</b> checkout.</p>

      Description

      ESD30 ESD Simulator Includes Everything for Testing:

      • ESD30 Handheld, battery operated ESD simulator
      • Battery charger/AC Adapter
      • Air discharge tip
      • Contact discharge
      • Ground cable 1 meter
      • Manual
      • Calibration Certificate
      • 10% off Calibration Service for Life of the Unit


      ESD30 30kV ESD Simulator for IEC/EN 61000-4-2

      The ESD30 30kV ESD Simulator is suitable for performing EMI tests on systems in accordance with the standard IEC / EN 61000-4-2 , MIL-STD-461G CS118, RTCA/DO-160 Section 25, IEC 60601-1-2 and many other ESD test standards. Higher test levels can be set far beyond the standard limits. Depending on the test object and test setup, two test methods are to be used:

      1. Air Discharge 
        In this case, the pulse is triggered by approaching the ESD16 towards the DUT. The high voltage applied to the discharge electrode is discharged suddenly, resulting in a very broadband highfrequency interference spectrum. This in turn can lead to influences on the test specimens.

      2. Contact Discharge 
        With this method, the probe of the generator is placed directly on the test object. The actual "impulse triggering" takes place via a relay contact and reduces the influencing factors such as approach speed, amplitude height, air humidity and temperature.
        Important: In the case of non-contacting (eg painted or oxidized surface), the impulses are not triggered. The display shows "No contact". This ensures that when triggering a discharge actually takes place.

      The contact discharge is the preferred test method since it is most reproducible. Air discharges are used when contact discharges are not possible - e.g. at plastic housings. The test voltages defined for each test method are shown in the table below:

      ESD30 Features

      • Programmable discharge voltage 200V to 30kV
      • Stabilized charging voltage
      • Pre-programmed IEC/EN 61000-4-2 test settings
      • True air-discharge breakdown voltage
      • Compact and lightweight design

      ESDguns.com is now a division of The EMC Shop

       

      Collections you may also like

      Send us a message!

      Do you need a formal quote?

      Recently viewed products

        Login

        Forgot your password?

        Don't have an account yet?