Ideal for voltage bleeding to Ground Plane during Indirect ESD Immunity...
Programmable discharge voltage 200 V to 16.5 kV Stabilized charging...
Suitable for EN/IEC 61000-4-2 ESD immunity compliance testing...
Programmable discharge voltage 500 V to 20 kV Pre-programmed IEC/EN...
Rental Package IncludesAir and Contact Discharge Tips Output...
Lightweight and ergonomical Pre-programmed Test Levels per IEC 61000-4-2...
Meets IEC/EN 61000-4-2 test settings Battery or mains operation...
ESD Guns can refurbish your existing INA 405 battery pack. Expected...
The Military Agency for Standardization (MAS) released this Standardization Agreement (STANAG 4239) outlining the electrostatic discharge test procedures in determining the safety and suitability for service of munitions containing electro explosive devices (EEDS) and associated electrical/electronic systems and subsystems, in the electrostatic environmental conditions specificed in STANAG 4235 for NATO forces. Guidance on electrostatic discharge (ESD) hazard assessment and testing is provided in AOP-24 document.
Testing to be performed in positive and negative polarities
Source of Threat | Voltage Across Capacitance | Capacitance | Resistance | Discharge Induction |
Personnel | 25kV ±5% | 500 pF ±5% | 5000 Ohms | <5 uH |
Personnel | 25kV ±5% | 500 pF ±5% | 500 Ohms | <5 uH |
Helicopter | 300kV ±5% | 1000 pF ±10% | 1 max* | <20 uH |
*Total distributed discharge circuit resistance measured with and accuracy