    Horizontal Coupling Plane for ISO 10605 Automotive ESD Test

      Description

      Annex F of the actual ISO 10605, provides an additional approach for the ESD powered up test. This approach is intended to produce more repeatable test results and to better correlate with vehicle level ESD tests and the real world environment in comparison especially to the HCP test. This test is an optional test that can be selected by the users in additional to the present standard ESD powered up test as described in clause 5.3. 

      The HCP-auto allows for direct and indirect application of ESD discharges to the DUT as per the automotive test standard ISO 10605 for electrostatic immunity, also reference by manufacturer specs by Ford, GM, Toyota and more.

      See Diagrams of Horizontal Coupling Plane (Pictures 2 and 3):

      1. Field Coupling Plane 
      2. Field Coupling Strip
      3. Discharge islands
      4. DUT and wiring harness isolation block
      5. DUT
      6. DUT wiring harness
      7. Battery
      8. Peripheral or support equipment
      9. AN (if used)
      10. Ground reference point for battery and support equipment
      11. DUT local ground,(if required)
      12. Ground reference point for ESD Coupling Plane, ESD generator and safety ground connection
      13. 2 x 470 kΩ high voltage resistors to satety ground
      14. HCP
      15. ESD generator main uni

        Horizontal Coupling Plane for ISO 10605 Automotive ESD Test

          Product form

          Request Lead Time

          $2,450.00 + Shipping

            Description of image
              Features

            • Compliant to Annex F of ISO 10605
            • 1500 mm Length

            Ask & Learn

            Previous answers and questions posted below

            Learn by asking questions, practicing, and getting guidance

            Ask Now

            Description

            Annex F of the actual ISO 10605, provides an additional approach for the ESD powered up test. This approach is intended to produce more repeatable test results and to better correlate with vehicle level ESD tests and the real world environment in comparison especially to the HCP test. This test is an optional test that can be selected by the users in additional to the present standard ESD powered up test as described in clause 5.3. 

            The HCP-auto allows for direct and indirect application of ESD discharges to the DUT as per the automotive test standard ISO 10605 for electrostatic immunity, also reference by manufacturer specs by Ford, GM, Toyota and more.

            See Diagrams of Horizontal Coupling Plane (Pictures 2 and 3):

            1. Field Coupling Plane 
            2. Field Coupling Strip
            3. Discharge islands
            4. DUT and wiring harness isolation block
            5. DUT
            6. DUT wiring harness
            7. Battery
            8. Peripheral or support equipment
            9. AN (if used)
            10. Ground reference point for battery and support equipment
            11. DUT local ground,(if required)
            12. Ground reference point for ESD Coupling Plane, ESD generator and safety ground connection
            13. 2 x 470 kΩ high voltage resistors to satety ground
            14. HCP
            15. ESD generator main uni

              Login