Send Enquiry For ETS Firing Test System Model 931
ETS Firing Test System Model 931
- Range: ±100 to ±26kV
- Capacitors: 100pf to 0.5μf
- Resistors: 0, 500, 1500 and 5000 Ω
- Custom resistor and capacitor networks
Programmable discharge voltage 200 V to 16.5 kV Stabilized charging...
Ideal for voltage bleeding to Ground Plane during Indirect ESD Immunity...
Rentals Ship Immediately Purchase Options See: Used Keytek Minizap ESD...
ESD Guns can refurbish your existing INA 405 battery pack. Expected...
Air- and Contact- Discharge: 1000 Volts - 20kV ±5% Rise time: 0.6-1ns RC...
Monthly Rentals Ship Today Order Online, Easy Checkout 2 Days Free...
Lightweight and ergonomical Pre-programmed Test Levels per IEC 61000-4-2...
Meets IEC 61000-4-2 VCP Aluminum 19.7" by 19.7" Wood Stand Cable with...
Test setups, or environments, are required to when performing ESD immunity testing to isolate the Equipment Under Test (EUT) and protect the technician from voltage exposure. The IEC 61000-4-2 test standards details specific requirements for table-top (large and small) and floor standing equipment. Components of the ESD test enviornment can be p...
Test setups, or environments, are required to when performing ESD immunity testing to isolate the Equipment Under Test (EUT) and protect the technician from voltage exposure. The IEC 61000-4-2 test standards details specific requirements for table-top (large and small) and floor standing equipment. Components of the ESD test enviornment can be purchased independently for post-installation and custom ESD testing.
Subcategories
ESDGuns.com is the only supplier of all ESD testing tables, components and accessories to help you meet IEC 61000-4-2, CE Mark and other electrostatic discharge compliance standards. An ESD test table typically includes a ground plane, hoizontal and vertical coupling planes, two grounding cables with 470 kOhm resistors and insulation material.
The IEC 61000-4-2 ESD immunity standards requires a cable with 470 kΩ bleeder resistors, shall be connected to the ground resistance plane (GRP) to both horizontal and coupling planes. Ungrounded EUT also require a resistive cable grounding the EUT to the horizontal coupling plane.
*The presence of the cable with the bleeder resistors can influence the test results of some equipment. In case of dispute, a test with the cable disconnected during the ESD pulse takes precedence over the test with the cable installed during the test, provided that the charge has sufficiently decayed between the successive discharges
Purchase associated items and replacement parts for your ESD test environment.